NFASS design, quote, install, and then commission fire alarm systems to suit their customer’s individual requirements. This involves regimentally following the British Standards and making the customer aware of any disturbance that will take place at the time of the installation.
Installation
The systems we install start from a small four-zone conventional system, they can escalate to large analogue networked systems. These systems are installed within many different environments from small offices to large commercial factories.
After the installation has been completed the customer or the nominated responsible person is fully trained on the daily and weekly inspection and testing on their system, including how to investigate any activations.
Experience has taught us that a customer that has significant training, will inspect their system on a regular basis and has no fear in testing the alarm. This prevents contravening BS 5839 and furthermore, will help stop any long-term problems arising by keeping NFASS informed.
Design & Contracting Installation
NFASS will happily design a system for your qualified approved electrical contractor to install. Many companies have their own electrical staff that are highly skilled but reluctant to install fire alarms. We can give basic training and guidance on the correct way to install the cabling, this is not a one-off meeting at the beginning, we will hand out a custom laminate guide, with clear-to-follow instructions and then visit the site to check the installation is running smoothly.
Furthermore, contact details are left to ensure any unforeseen problems are hopefully resolved quickly.
It is not our place to tell qualified electricians how to do their job, instead, we are here to keep your prices down and help guide electricians on the British Standards.
This can be done in several ways, the most common use of our training, experience, and certifications are:-
System Design Only
- After receiving a pdf format plan we will insert British Standard icons.
- Create a location report with a device list.
Design - Supply and Commission
- As in (1) with the addition of supplying all the open protocol equipment.
- Visiting site at completion to commission the system with the relevant certification.
- Training the end user on their system.
- Supplying a maintenance schedule to ensure continuity of end user testing on their system (BS 5839 Requirement).
Design - Supply - Installation Training and Commission
- As in (1 & 2) with the addition of basic training of the qualified electricians.
- Including a laminate sheet highlighting parts of the British Standards.
- A second site visit to ensure the work is being completed following the specifications.
- Phone support to help avoid problems at the installation stage.
Design - Supply - Installation Training - Second Fixing and Commission
- As in (1 to 3) with the addition of installing the equipment on the cabling installed by others.
- On analogue systems this includes creating numbered labels for the various alarm devices.
- Supplying an electronic copy of all notes, plans, reading and software programming.
Complete Installation
- As in (1 to 4) with the addition of supplying and installing the cabling.
Routine Maintenance
When asked to tender for the maintenance of an existing system installed by another contractor, we will visit the site and quote using a summarized equipment report. After the tender has been accepted, we contact the customer to schedule an appointment making the client aware of the access required throughout the property and the short noise bursts involved in testing the system correctly
At the end of the first service inspection, the customer will be asked for any previous logbooks and will then be shown how to test their system with a hands-on training session.
When returning to the office, a full location report will be created including any recommendations or faults that were discovered during the inspection. Furthermore, if the system was functioning correctly and did not contravene with the British standards, a certificate will be generated, with a copy electronically archived.
Custom Reports
Many of our larger customers are starting to realise that the larger contractors cannot survey their sites and give detailed reports stating the condition of their emergency lighting and fire alarm systems.
NFASS offer a be-spoke reporting, service inspection, and certification schedule, that identifies their immediate faults and future system expense (i.e. emergency lighting batteries). This will allow budget planning and help eliminate future system failures.
With the larger clients who have in-house electrical staff, we train the engineers to undertake the once-a-year smaller inspection, then NFASS will return six months later to initiate the larger service with certification. This routine will minimize their maintenance costs, and ensure constant monitoring of their systems, with the reassurance that their staff is working to the latest standards.